Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 173
Filter
1.
Talanta ; 262: 124701, 2023 Sep 01.
Article in English | MEDLINE | ID: covidwho-2324697

ABSTRACT

Fast and effective diagnosis is the first step in monitoring the current coronavirus 2 (CoV-2) pandemic. Herein, we establish a simple and sensitive electrochemical assay using magnetic nanocomposite and DNA sandwich probes to rapidly quantify the CoV-2 nucleocapsid (N) gene down to the 0.37 fM level. This assay uses a pair of specific DNA probes. The capture probe is covalently conjugated to Au-decorated magnetic reduced graphene oxide (AMrGO) nanocomposite for efficiently capturing target RNA. In contrast, the detection probe is linked to peroxidase for signal amplification. The probes target the COV-2 gene, allowing for specific magnetic separation, enzymatic signal amplification, and subsequent generation of voltammetric current with a total assay time of 45 min. The developed biosensor has high selectivity and can discriminate non-specific gene sequences. Synthetic COV-2 N-gene can be detected efficiently in serum and saliva, while 1-bp mismatch gene yielded a low response. The performance of the genosensor was good in an extensive linear range of 5 aM-50 pM. For synthetic N-gene, we achieved the detection limit of 0.37, 0.33, and 0.19 fM in human saliva, urine, and serum. This simple, selective, and sensitive genosensor could have various genetics-based biosensing and diagnostic applications.


Subject(s)
Biosensing Techniques , COVID-19 , Graphite , Nanocomposites , Humans , SARS-CoV-2/genetics , Graphite/chemistry , Nanocomposites/chemistry , Nucleocapsid , Electrochemical Techniques , Gold/chemistry
2.
Biosensors (Basel) ; 13(4)2023 Apr 03.
Article in English | MEDLINE | ID: covidwho-2326319

ABSTRACT

Electrochemical sensors consisting of screen-printed electrodes (SPEs) are recurrent devices in the recent literature for applications in different fields of interest and contribute to the expanding electroanalytical chemistry field. This is due to inherent characteristics that can be better (or only) achieved with the use of SPEs, including miniaturization, cost reduction, lower sample consumption, compatibility with portable equipment, and disposability. SPEs are also quite versatile; they can be manufactured using different formulations of conductive inks and substrates, and are of varied designs. Naturally, the analytical performance of SPEs is directly affected by the quality of the material used for printing and modifying the electrodes. In this sense, the most varied carbon nanomaterials have been explored for the preparation and modification of SPEs, providing devices with an enhanced electrochemical response and greater sensitivity, in addition to functionalized surfaces that can immobilize biological agents for the manufacture of biosensors. Considering the relevance and timeliness of the topic, this review aimed to provide an overview of the current scenario of the use of carbonaceous nanomaterials in the context of making electrochemical SPE sensors, from which different approaches will be presented, exploring materials traditionally investigated in electrochemistry, such as graphene, carbon nanotubes, carbon black, and those more recently investigated for this (carbon quantum dots, graphitic carbon nitride, and biochar). Perspectives on the use and expansion of these devices are also considered.


Subject(s)
Biosensing Techniques , Nanotubes, Carbon , Electrodes , Electrochemistry , Electrochemical Techniques
3.
Molecules ; 28(9)2023 Apr 27.
Article in English | MEDLINE | ID: covidwho-2313883

ABSTRACT

Electrochemical biosensors are known as analytical tools, guaranteeing rapid and on-site results in medical diagnostics, food safety, environmental protection, and life sciences research. Current research focuses on developing sensors for specific targets and addresses challenges to be solved before their commercialization. These challenges typically include the lowering of the limit of detection, the widening of the linear concentration range, the analysis of real samples in a real environment and the comparison with a standard validation method. Nowadays, functional nanomaterials are designed and applied in electrochemical biosensing to support all these challenges. This review will address the integration of functional nanomaterials in the development of electrochemical biosensors for the rapid diagnosis of viral infections, such as COVID-19, middle east respiratory syndrome (MERS), influenza, hepatitis, human immunodeficiency virus (HIV), and dengue, among others. The role and relevance of the nanomaterial, the type of biosensor, and the electrochemical technique adopted will be discussed. Finally, the critical issues in applying laboratory research to the analysis of real samples, future perspectives, and commercialization aspects of electrochemical biosensors for virus detection will be analyzed.


Subject(s)
Biological Science Disciplines , Biosensing Techniques , COVID-19 , Nanostructures , Humans , COVID-19/diagnosis , Biosensing Techniques/methods , Electrochemical Techniques
4.
Bioelectrochemistry ; 152: 108462, 2023 Aug.
Article in English | MEDLINE | ID: covidwho-2320689

ABSTRACT

Sensitive detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) spike protein (S protein) is of significant clinical importance in the diagnosis of COVID-19 pandemic. In this work, a surface molecularly imprinted (SMI) electrochemical biosensor is fabricated for the detection of SARS-CoV-2 S protein. Cu7S4-Au is used as the built-in probe and modified on the surface of a screen-printed carbon electrode (SPCE). 4-Mercaptophenylboric acid (4-MPBA) is anchored to the surface of the Cu7S4-Au through Au-SH bonds, which can be used for the immobilization of the SARS-CoV-2 S protein template through boronate ester bonds. After that, 3-aminophenylboronic acid (3-APBA) is electropolymerized on the electrode surface and used as the molecularly imprinted polymers (MIPs). The SMI electrochemical biosensor is obtained after the elution of the SARS-CoV-2 S protein template with an acidic solution by the dissociation of the boronate ester bonds, which can be utilized for sensitive detection of the SARS-CoV-2 S protein. The developed SMI electrochemical biosensor displays high specificity, reproducibility and stability, which might be a potential and promising candidate for the clinical diagnosis of COVID-19.


Subject(s)
Biosensing Techniques , COVID-19 , Humans , Spike Glycoprotein, Coronavirus , COVID-19/diagnosis , Electrochemical Techniques , SARS-CoV-2 , Reproducibility of Results , Pandemics
5.
Talanta ; 263: 124678, 2023 Oct 01.
Article in English | MEDLINE | ID: covidwho-2320337

ABSTRACT

As a common antioxidant and nutritional fortifier in food chemistry, rutin has positive therapeutic effects against novel coronaviruses. Here, Ce-doped poly(3,4-ethylenedioxythiophene) (Ce-PEDOT) nanocomposites derived through cerium-based metal-organic framework (Ce-MOF) as a sacrificial template have been synthesized and successfully applied to electrochemical sensors. Due to the outstanding electrical conductivity of PEDOT and the high catalytic activity of Ce, the nanocomposites were used for the detection of rutin. The Ce-PEDOT/GCE sensor detects rutin over a linear range of 0.02-9 µM with the limit of detection of 14.7 nM (S/N = 3). Satisfactory results were obtained in the determination of rutin in natural food samples (buckwheat tea and orange). Moreover, the redox mechanism and electrochemical reaction sites of rutin were investigated by the CV curves of scan rate and density functional theory. This work is the first to demonstrate the combined PEDOT and Ce-MOF-derived materials as an electrochemical sensor to detect rutin, thus opening a new window for the application of the material in detection.


Subject(s)
Cerium , Metal-Organic Frameworks , Rutin , Polymers , Electrochemical Techniques/methods
6.
Talanta ; 260: 124604, 2023 Aug 01.
Article in English | MEDLINE | ID: covidwho-2316564

ABSTRACT

Herein, a ternary PdPtRu nanodendrite as novel trimetallic nanozyme was reported, which possessed excellent peroxidase-like activity as well as electro-catalytic activity on account of the synergistic effect between the three metals. Based on the excellent electro-catalytic activity of trimetallic PdPtRu nanozyme toward the reduction of H2O2, the trimetallic nanozyme was applied to construct a brief electrochemical immunosensor for SARS-COV-2 antigen detection. Concretely, trimetallic PdPtRu nanodendrite was used to modify electrode surface, which not only generated high reduction current of H2O2 for signal amplification, but also provided massive active sites for capture antibody (Ab1) immobilization to construct immunosensor. In the presence of target SARS-COV-2 antigen, SiO2 nanosphere labeled detection antibody (Ab2) composites were introduced on the electrode surface according sandwich immuno-reaction. Due to the inhibitory effect of SiO2 nanosphere on the current signal, the current signal was decreased with the increasing target SARS-COV-2 antigen concentration. As a result, the proposed electrochemical immunosensor presented sensitive detection of SARS-COV-2 antigen with linear range from 1.0 pg/mL to 1.0 µg/mL and limit of detection down to 51.74 fg/mL. The proposed immunosensor provide a brief but sensitive antigen detection tool for rapid diagnosis of COVID-19.


Subject(s)
Biosensing Techniques , COVID-19 , Metal Nanoparticles , Humans , Metal Nanoparticles/chemistry , SARS-CoV-2 , Immunoassay , Hydrogen Peroxide/chemistry , Silicon Dioxide , COVID-19/diagnosis , Antibodies , Antibodies, Immobilized/chemistry , Gold/chemistry , Electrochemical Techniques , Limit of Detection
7.
Biosensors (Basel) ; 13(4)2023 Mar 23.
Article in English | MEDLINE | ID: covidwho-2315555

ABSTRACT

Biosensors are analytical tools that can be used as simple, real-time, and effective devices in clinical diagnosis, food analysis, and environmental monitoring. Nanoscale functional materials possess unique properties such as a large surface-to-volume ratio, making them useful for biomedical diagnostic purposes. Nanoengineering has resulted in the increased use of nanoscale functional materials in biosensors. Various types of nanostructures i.e., 0D, 1D, 2D, and 3D, have been intensively employed to enhance biosensor selectivity, limit of detection, sensitivity, and speed of response time to display results. In particular, carbon nanotubes and nanofibers have been extensively employed in electrochemical biosensors, which have become an interdisciplinary frontier between material science and viral disease detection. This review provides an overview of the current research activities in nanofiber-based electrochemical biosensors for diagnostic purposes. The clinical applications of these nanobiosensors are also highlighted, along with a discussion of the future directions for these materials in diagnostics. The aim of this review is to stimulate a broader interest in developing nanofiber-based electrochemical biosensors and improving their applications in disease diagnosis. In this review, we summarize some of the most recent advances achieved in point of care (PoC) electrochemical biosensor applications, focusing on new materials and modifiers enabling biorecognition that have led to improved sensitivity, specificity, stability, and response time.


Subject(s)
Biosensing Techniques , Nanofibers , Nanostructures , Nanotubes, Carbon , Electrochemical Techniques/methods , Nanostructures/chemistry , Biosensing Techniques/methods
8.
Anal Chim Acta ; 1265: 341326, 2023 Jul 18.
Article in English | MEDLINE | ID: covidwho-2311677

ABSTRACT

Herein, we have proposed a straightforward and label-free electrochemical immunosensing strategy supported on a glassy carbon electrode (GCE) modified with a biocompatible and conducting biopolymer functionalized molybdenum disulfide-reduced graphene oxide (CS-MoS2/rGO) nanohybrid to investigate the SARS-CoV-2 virus. CS-MoS2/rGO nanohybrid-based immunosensor employs recombinant SARS-CoV-2 Spike RBD protein (rSP) that specifically identifies antibodies against the SARS-CoV-2 virus via differential pulse voltammetry (DPV). The antigen-antibody interaction diminishes the current responses of the immunosensor. The obtained results indicate that the fabricated immunosensor is extraordinarily capable of highly sensitive and specific detection of the corresponding SARS-CoV-2 antibodies with a LOD of 2.38 zg mL-1 in phosphate buffer saline (PBS) samples over a broad linear range between 10 zg mL-1-100 ng mL-1. In addition, the proposed immunosensor can detect attomolar concentrations in spiked human serum samples. The performance of this immunosensor is assessed using actual serum samples from COVID-19-infected patients. The proposed immunosensor can accurately and substantially differentiate between (+) positive and (-) negative samples. As a result, the nanohybrid can provide insight into the conception of Point-of-Care Testing (POCT) platforms for cutting-edge infectious disease diagnostic methods.


Subject(s)
Biosensing Techniques , COVID-19 , Graphite , Metal Nanoparticles , Humans , Molybdenum , Biosensing Techniques/methods , COVID-19/diagnosis , Immunoassay/methods , SARS-CoV-2 , Electrochemical Techniques/methods
9.
Talanta ; 260: 124614, 2023 Aug 01.
Article in English | MEDLINE | ID: covidwho-2311488

ABSTRACT

A novel immunosensor based on electrochemiluminescence resonance energy transfer (ECL-RET) for the sensitive determination of N protein of the SARS-CoV-2 coronavirus is described. For this purpose, bifunctional core@shell nanoparticles composed of a Pt-coated Au core and finally decorated with small Au inlays (Au@Pt/Au NPs) have been synthesized to act as ECL acceptor, using [Ru (bpy)3]2+ as ECL donor. These nanoparticles are efficient signaling probes in the immunosensor developed. The proposed ECL-RET immunosensor has a wide linear response to the concentration of N protein of the SARS-CoV-2 coronavirus with a detection limit of 1.27 pg/mL. Moreover, it has a high stability and shows no response to other proteins related to different virus. The immunosensor has achieved the quantification of N protein of the SARS-CoV-2 coronavirus in saliva samples. Results are consistent with those provided by a commercial colorimetric ELISA kit. Therefore, the developed immunosensor provides a feasible and reliable tool for early and effective detection of the virus to protect the population.


Subject(s)
Biosensing Techniques , COVID-19 , Metal Nanoparticles , Humans , Gold , SARS-CoV-2 , Luminescent Measurements/methods , Biosensing Techniques/methods , Immunoassay/methods , COVID-19/diagnosis , Electrochemical Techniques/methods , Limit of Detection
10.
Biosens Bioelectron ; 215: 114580, 2022 Nov 01.
Article in English | MEDLINE | ID: covidwho-2311736

ABSTRACT

Rational detection of syndrome coronavirus 2 (SARS-CoV-2) is crucial to prevention, control, and treatment of disease. Herein, a dual-wavelength ratiometric electrochemiluminescence (ECL) biosensor based on resonance energy transfer (RET) between g-C3N4 nanosheets and Ru-SiO2@folic acid (FA) nanomaterials was designed to realize ultrasensitive detection of SARS-CoV-2 virus (RdRp gene). Firstly, the unique g-C3N4 nanosheets displayed very intense and stable ECL at 460 nm, then the triple helix DNA was stably and vertically bound to g-C3N4 on electrode by high binding affinity between ssDNA and g-C3N4. Meanwhile, trace amounts of target genes were converted to a large number of output by three-dimensional (3D) DNA walker multiple amplification, and the output bridged a multifunctional probe Ru-SiO2@FA to electrode. Ru-SiO2@FA not only showed high ECL at 620 nm, but also effectively quenched g-C3N4 ECL. As a result, ECL decreased at 460 nm and increased at 620 nm, which was used to design a rational ECL biosensor for detection of SARS gene. The results show that the biosensor has excellent detection sensitivity for RdRp gene with a dynamic detection range of 1 fM to 10 nM and a limit of detection (LOD) of 0.18 fM. The dual-wavelength ratio ECL biosensor has inestimable value and application prospects in the fields of biosensing and clinical diagnosis.


Subject(s)
Biosensing Techniques , COVID-19 , Biosensing Techniques/methods , COVID-19/diagnosis , DNA , Electrochemical Techniques/methods , Energy Transfer , Folic Acid , Humans , Limit of Detection , Luminescent Measurements/methods , Nanostructures , RNA-Dependent RNA Polymerase , Ruthenium , SARS-CoV-2/genetics , Silicon Dioxide
11.
Biosens Bioelectron ; 226: 115104, 2023 Apr 15.
Article in English | MEDLINE | ID: covidwho-2307021

ABSTRACT

The separation of the superimposed electrochemical signals of intracellular guanine (G) and xanthine (X) is difficult, which is great obstacle to the application of cell electrochemistry. In this paper, independent functional modules, G-functional module (G-FM) and X-functional module (X-FM), were constructed by molecular imprinting technology for sensitive detection of G and X without mutual interference, then integrated in dual-functional module cellular electrochemical sensing platform (DMCEP) as signal sensing units. DMCEP transmitted signals of G and X in cells synchronously to two windows by two signal sensing channels, and achieved the separation of superimposed signals of G and X in cells. DMCEP exhibited satisfactory reproducibility with relative standard deviation (RSD) of 3.10 and 2.22 %, repeatability with RSD of 3.72 and 3.05 % for G and X detection, and detection limit 0.05 µΜ for G and 0.06 µΜ for X. Good linear relationships between cell concentrations and the signals of G and X on DMCEP were shown in range of 0.75-85 × 106 and 3-85 × 106 cells/mL, respectively. The growth of MCF-7 cells was tracked by DMCEP, and showed consistent trend with the cell counting method, while the change of cell viability from lag to logarithmic phase captured by DMCEP was earlier than that of cell counting method. This strategy provided the foundation for the establishment of the cell viability electrochemical detection method, and new insights into the simultaneous recording of other analyses with superimposed peak positions and the simultaneous tracking of multiple biomarkers.


Subject(s)
Biosensing Techniques , Guanine , Humans , Xanthine , Guanine/analysis , Reproducibility of Results , MCF-7 Cells , Electrochemical Techniques , Limit of Detection , Electrodes
12.
Bioelectrochemistry ; 152: 108434, 2023 Aug.
Article in English | MEDLINE | ID: covidwho-2300718

ABSTRACT

For clinical research, the precise measurement of hydrogen peroxide (H2O2) and glucose (Glu) is of paramount importance, due to their imbalanced concentrations in blood glucose, and reactive oxygen species (ROS) play a huge role in COVID-19 viral disease. It is critical to construct and develop a simple, rapid, flexible, long-term, and sensitive detection of H2O2 and glucose. In this paper, we have developed a unique morphological structure of MOF(Cu) on a single-walled carbon nanotube-modified gold wire (swnt@gw). Highly designed frameworks with nanotube composites enhance electron rate-transfer behavior while extending conductance and electroactive surface area.The composite sensing system delivers wide linear-range concentrations, low detection limit, and interference-free performance in co-existence with other biomolecules and metal ions. Endogenous quantitative tracking of H2O2 was performed in macrophage live-cells with the help of a strong stimulator lipopolysaccharide.The composite device was effectively utilized for the measurement of H2O2 and glucose in turbid samples of whole blood and milk samples without a pretreatment process. The practical results of biofluids showed favorable voltammetric results and acceptance recovery percentage levels between 97.49 and 98.88%. Finally, a flexible MOF-based hybrid system may provide a suitable detection platform in the construction of electro-biosensors and hold potential promise for clinical-sensory applications.


Subject(s)
Biosensing Techniques , COVID-19 , Humans , Copper/chemistry , Gold/chemistry , Hydrogen Peroxide/chemistry , Glucose , Biosensing Techniques/methods , Electrochemical Techniques/methods , Limit of Detection
13.
Anal Biochem ; 662: 115013, 2023 02 01.
Article in English | MEDLINE | ID: covidwho-2298807

ABSTRACT

This study developed a novel, ultrasensitive sandwich-type electrochemical immunosensor for detecting the porcine epidemic diarrhea virus (PEDV). By electrochemical co-deposition of graphene and Prussian blue, a Prussian blue-reduced graphene oxide-modified glassy carbon electrode was made, further modified with PEDV-monoclonal antibodies (mAbs) to create a new PEDV immunosensor using the double antibody sandwich technique. The electrochemical characteristics of several modified electrodes were investigated using cyclic voltammetry (CV). We optimized the pH levels and scan rate. Additionally, we examined specificity, reproducibility, repeatability, accuracy, and stability. The study indicates that the immunosensor has good performance in the concentration range of 1 × 101.88 to 1 × 105.38 TCID50/mL of PEDV, with a detection limit of 1 × 101.93 TCID50/mL at a signal-to-noise ratio of 3σ. The composite membranes produced via co-deposition of graphene and Prussian blue effectively increased electron transport to the glassy carbon electrode, boosted response signals, and increased the sensitivity, specificity, and stability of the immunosensor. The immunosensor could accurately detect PEDV, with results comparable to real-time quantitative PCR. This technique was applied to PEDV detection and served as a model for developing additional immunosensors for detecting hazardous chemicals and pathogenic microbes.


Subject(s)
Biosensing Techniques , Graphite , Porcine epidemic diarrhea virus , Animals , Swine , Carbon , Biosensing Techniques/methods , Electrochemical Techniques/methods , Reproducibility of Results , Immunoassay/methods , Electrodes , Limit of Detection , Gold
14.
Biosensors (Basel) ; 13(4)2023 Apr 18.
Article in English | MEDLINE | ID: covidwho-2295971

ABSTRACT

Herein, we report results of the studies relating to the development of an impedimetric, magnetic bead-assisted supersandwich DNA hybridization assay for ultrasensitive detection of Neisseria gonorrhoeae, the causative agent of a sexually transmitted infection (STI), gonorrhea. First, a conductive ink was formulated by homogenously dispersing carboxylated multiwalled carbon nanotubes (cMWCNTs) in a stable emulsion of terpineol and an aqueous suspension of carboxymethyl cellulose (CMC). The ink, labeled C5, was coated onto paper substrates to fabricate C5@paper conductive electrodes. Thereafter, a magnetic bead (MB)-assisted supersandwich DNA hybridization assay was optimized against the porA pseudogene of N. gonorrhoeae. For this purpose, a pair of specific 5' aminated capture probes (SCP) and supersandwich detector probes (SDP) was designed, which allowed the enrichment of target gonorrheal DNA sequence from a milieu of substances. The SD probe was designed such that instead of 1:1 binding, it allowed the binding of more than one T strand, leading to a 'ladder-like' DNA supersandwich structure. The MB-assisted supersandwich assay was integrated into the C5@paper electrodes for electrochemical analysis. The C5@paper electrodes were found to be highly conductive by a four-probe conductivity method (maximum conductivity of 10.1 S·cm-1). Further, the biosensing assay displayed a wide linear range of 100 aM-100 nM (109 orders of magnitude) with an excellent sensitivity of 22.6 kΩ·(log[concentration])-1. The clinical applicability of the biosensing assay was assessed by detecting genomic DNA extracted from N. gonorrhoeae in the presence of DNA from different non-gonorrheal bacterial species. In conclusion, this study demonstrates a highly sensitive, cost-effective, and label-free paper-based device for STI diagnostics. The ink formulation prepared for the study was found to be highly thixotropic, which indicates that the paper electrodes can be screen-printed in a reproducible and scalable manner.


Subject(s)
Biosensing Techniques , Gonorrhea , Nanotubes, Carbon , Humans , Neisseria gonorrhoeae/genetics , Nanotubes, Carbon/chemistry , Ink , DNA/analysis , Gonorrhea/diagnosis , Biosensing Techniques/methods , Electrochemical Techniques/methods , Electrodes
15.
Molecules ; 28(8)2023 Apr 20.
Article in English | MEDLINE | ID: covidwho-2293250

ABSTRACT

Disease-related biomarkers may serve as indicators of human disease. The clinical diagnosis of diseases may largely benefit from timely and accurate detection of biomarkers, which has been the subject of extensive investigations. Due to the specificity of antibody and antigen recognition, electrochemical immunosensors can accurately detect multiple disease biomarkers, including proteins, antigens, and enzymes. This review deals with the fundamentals and types of electrochemical immunosensors. The electrochemical immunosensors are developed using three different catalysts: redox couples, typical biological enzymes, and nanomimetic enzymes. This review also focuses on the applications of those immunosensors in the detection of cancer, Alzheimer's disease, novel coronavirus pneumonia and other diseases. Finally, the future trends in electrochemical immunosensors are addressed in terms of achieving lower detection limits, improving electrode modification capabilities and developing composite functional materials.


Subject(s)
Biosensing Techniques , COVID-19 , Humans , Immunoassay , Electrochemical Techniques , COVID-19/diagnosis , Biomarkers
16.
Biosens Bioelectron ; 225: 115101, 2023 Apr 01.
Article in English | MEDLINE | ID: covidwho-2288794

ABSTRACT

The electrochemical biosensor with outstanding sensitivity and low cost is regarded as a viable alternative to current clinical diagnostic techniques for various disease biomarkers. However, their actual analytical use in complex biological samples is severely hampered due to the biofouling, as they are also highly sensitive to nonspecific adsorption on the sensing interfaces. Herein, we have constructed a non-fouling electrochemical biosensor based on antifouling peptides and the electroneutral peptide nucleic acid (PNA), which was used as the recognizing probe for the specific binding of the viral RNA of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Different from the negatively charged DNA probes that will normally weaken the biosensors' antifouling capabilities owing to the charge attraction of positively charged biomolecules, the neutral PNA probe will generate no side-effects on the biosensor. The biosensor demonstrated remarkable sensitivity in detecting SARS-CoV-2 viral RNA, possessing a broad linear range (1.0 fM - 1.0 nM) and a detection limit down to 0.38 fM. Furthermore, the sensing performance of the constructed electrochemical biosensor in human saliva was nearly similar to that in pure buffer, indicating satisfying antifouling capability. The combination of PNA probes with antifouling peptides offered a new strategy for the development of non-fouling sensing systems capable of assaying trace disease biomarkers in complicated biological media.


Subject(s)
Biofouling , Biosensing Techniques , COVID-19 , Nucleic Acids , Peptide Nucleic Acids , Humans , Peptide Nucleic Acids/chemistry , Biofouling/prevention & control , Saliva , Biosensing Techniques/methods , COVID-19/diagnosis , Electrochemical Techniques/methods , SARS-CoV-2 , Peptides/chemistry , Biomarkers
17.
Sci Rep ; 13(1): 5139, 2023 03 29.
Article in English | MEDLINE | ID: covidwho-2263674

ABSTRACT

SARS-CoV-2 caused a global panic among populations. Rapid diagnostic procedures for the virus are crucial for disease control. Thus, the designed signature probe from a highly conserved region of the virus was chemically immobilized onto the nanostructured-AuNPs/WO3-screen printed electrodes. Different concentrations of the matched oligonucleotides were spiked to test the specificity of the hybridization affinity whereas the electrochemical impedance spectroscopy was used for tracking the electrochemical performance. After a full assay optimization, limits of detection and quantification were calculated based on linear regression and were valued at 298 and 994 fM, respectively. Further, the high performance of the fabricated RNA-sensor chips was confirmed after testing the interference status in the presence of the mismatched oligos in one nucleotide and completely one. Worthy to mention that the single-stranded matched oligos can be hybridized to the immobilized probe in 5 min at room temperature. The designed disposable sensor chips are capable of detecting the virus genome directly. Therefore, the chips are a rapid tool for SARS-CoV-2 detection.


Subject(s)
Biosensing Techniques , COVID-19 , Metal Nanoparticles , Humans , SARS-CoV-2/genetics , Gold/chemistry , COVID-19/diagnosis , Metal Nanoparticles/chemistry , Electrodes , RNA , Biosensing Techniques/methods , Electrochemical Techniques/methods
18.
Biosensors (Basel) ; 13(2)2023 Jan 31.
Article in English | MEDLINE | ID: covidwho-2259573

ABSTRACT

Catecholamines, including dopamine, epinephrine, and norepinephrine, are considered one of the most crucial subgroups of neurotransmitters in the central nervous system (CNS), in which they act at the brain's highest levels of mental function and play key roles in neurological disorders. Accordingly, the analysis of such catecholamines in biological samples has shown a great interest in clinical and pharmaceutical importance toward the early diagnosis of neurological diseases such as Epilepsy, Parkinson, and Alzheimer diseases. As promising routes for the real-time monitoring of catecholamine neurotransmitters, optical and electrochemical biosensors have been widely adopted and perceived as a dramatically accelerating development in the last decade. Therefore, this review aims to provide a comprehensive overview on the recent advances and main challenges in catecholamines biosensors. Particular emphasis is given to electrochemical biosensors, reviewing their sensing mechanism and the unique characteristics brought by the emergence of nanotechnology. Based on specific biosensors' performance metrics, multiple perspectives on the therapeutic use of nanomaterial for catecholamines analysis and future development trends are also summarized.


Subject(s)
Biosensing Techniques , Nanostructures , Catecholamines , Electrochemical Techniques , Neurotransmitter Agents
19.
Chembiochem ; 24(9): e202300030, 2023 05 02.
Article in English | MEDLINE | ID: covidwho-2276697

ABSTRACT

One of the main problems in developing immunosensors featuring carbon nanotubes (CNTs) is immobilizing antibodies (Abs) onto the CNT surface to afford selective binding to target antigens (Ags). In this work, we developed a practical supramolecular Ab conjugation strategy based on resorc[4]arene modifiers. To improve the Ab orientation on the CNTs surface and optimizing the Ab/Ag interaction, we exploited the host-guest approach by synthesizing two newly resorc[4]arene linkers R1 and R2 via well-established procedures. The upper rim was decorated with eight methoxyl groups to promote selective recognition of the fragment crystallizable (Fc ) region of the Ab. Moreover, the lower rim was functionalized with 3-bromopropyloxy or 3-azidopropiloxy substituents to bind the macrocycles on the multi-walled carbon nanotubes (MWCNTs) surface. Accordingly, several chemical modifications of MWCNTs were evaluated. After the morphological and electrochemical characterization of nanomaterials, the resorc[4]arene-modified MWCNTs were deposited onto a glassy carbon electrode surface to evaluate their potential applicability for label-free immunosensor development. The most promising system showed an improved electrode active area (AEL ) of almost 20 % and a site-oriented immobilization of the SARS-CoV-2 spike protein S1 antibody (Ab-SPS1). The developed immunosensor revealed a good sensitivity (23.64 µA mL ng-1 cm-2 ) towards the SPS1 antigen and a limit of detection (LOD) of 1.01 ng mL-1 .


Subject(s)
Biosensing Techniques , COVID-19 , Nanotubes, Carbon , Humans , Biosensing Techniques/methods , Nanotubes, Carbon/chemistry , Immunoassay , SARS-CoV-2 , Antibodies/chemistry , Antigens , Limit of Detection , Electrochemical Techniques/methods , Gold/chemistry
20.
Anal Bioanal Chem ; 415(8): 1559-1570, 2023 Mar.
Article in English | MEDLINE | ID: covidwho-2258083

ABSTRACT

A novel voltammetric platform based on pencil graphite electrode (PGE) modification has been proposed, containing bimetallic (NiFe) Prussian blue analogue nanopolygons decorated with electro-polymerized glyoxal polymer nanocomposites (p-DPG NCs@NiFe PBA Ns/PGE). Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and square wave voltammetry (SWV) were utilized to investigate the electrochemical performance of the proposed sensor. The analytical response of p-DPG NCs@NiFe PBA Ns/PGE was evaluated through the quantity of amisulpride (AMS), one of the most common antipsychotic drugs. Under the optimized experimental and instrumental conditions, the method showed linearity over the range from 0.5 to 15 × 10-8 mol L-1 with a good correlation coefficient (R = 0.9995) and a low detection limit (LOD) reached, 1.5 nmol L-1, with excellent relative standard deviation for human plasma and urine samples. The interference effect of some potentially interfering substances was negligible, and the sensing platform demonstrated an outstanding reproducibility, stability, and reusability. As a first trial, the proposed electrode aimed to shed light on the AMS oxidation mechanism, where the oxidation mechanism was monitored and elucidated using the FTIR technique. It was also found that the prepared p-DPG NCs@NiFe PBA Ns/PGE platform had promising applications for the simultaneous determination of AMS in the presence of some co-administered COVID-19 drugs, which could be attributed to the large active surface area, and high conductivity of bimetallic nanopolygons.


Subject(s)
COVID-19 , Graphite , Humans , Electrochemical Techniques/methods , Amisulpride , Polymers/chemistry , Reproducibility of Results , Electrodes , Graphite/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL